一、起水泡原因:1)结构体地下层、水箱旁、底楼层或其它地面水气湿度偏高;2)没做防水处理或底漆封闭不良。预防方法:1、施工前先以水份计协助判断;2、水份及水压太高的地点须先做防水处理;3、选择水性的环氧树脂底漆。
The causes of blistering are as follows: 1) high moisture in the underground layer, near the water tank, bottom floor or other ground floor; 2) no waterproof treatment or poor sealing of primer. Preventive methods: 1. Use moisture meter to assist in judging before construction; 2. Waterproof treatment should be done in places with too high water content and pressure; 3. Select waterborne epoxy resin primer.
二、色差
Two, chromatic aberration
原因:
Reason:
1、环氧树脂地坪涂料主剂沉淀,未充分搅拌均匀;
1. The main agent of epoxy floor coating is precipitated and not fully stirred uniformly.
2、倒料在地面上,与前接缝处之接触时间过久;
2. The contact time between the material and the front joint is too long when the material is dumped on the ground.
3、涂层厚薄不均匀;
3. Coating thickness is not uniform.
4、施工中途断料;
4. Material breakage during construction;
5、采用不同批号面漆。
5. Different batches of topcoats.
预防方法:
Prevention methods:
1、施工前主剂应先充分搅拌均匀;
1. The main agent should be fully stirred and evenly mixed before construction.
2、避免与前接缝处接触间隔太久,尽可能整个操作线一起施工;
2. Avoid long contact interval with the front joint, and construct the whole operation line as far as possible.
3、尽量适用固定工具及加强施工人员施工熟练度;
3. Apply fixed tools as far as possible and strengthen construction skillfulness of constructors;
4、涂料须一次备足,防止断料;
4. Coatings should be prepared at one time to prevent material breakage.
5、尽可能使用同一批号涂料。
5. Use the same batch of paint as far as possible.
三、火山口
III. craters
原因:
Reason:
1、下层有坑洞;
1. There are holes in the lower layer.
2、下层有油污;
2. Oil pollution in the lower layer;
3、涂料本身原因。
3. Reasons for paint itself.
预防方法:
Prevention methods:
1、施工前先用环氧批土把坑洞修补平后再进行施工;
1. Before construction, epoxy batch earth is used to repair and flatten the pit before construction.
2、将下层油污清除干净;
2. Clean up the oil pollution in the lower layer.
3、先用合适的涂料。
3. Use appropriate coatings first.
四、发白
Four, whitening
原因:
Reason:
1、冬天油漆反应速度过慢,用硬化剂与空气反应产生白雾状;
1. In winter, the reaction speed of paint is too slow, and the hardener reacts with air to produce white fog.
2、在低温多湿之场合施工;
2. Construction at low temperature and humidity.
3、施工后遭水侵入。
3. Water intrusion after construction.
预防方法:
Prevention methods:
1、选择适当硬化剂;
1. Selecting appropriate hardener;
2、避免低温多湿条件施工,不得已时采取加温除湿措施,如空调加温降湿,暖风机加温;
2. In order to avoid construction under low temperature and humidity conditions, heating and dehumidification measures should be taken when necessary, such as air conditioning heating and dehumidification, and heater heating.
3、避免施工后有水侵入。
3. Avoid water intrusion after construction. 本站网址:http://www.wuxispeed.com
|